Fluke Networks Fiber QuickMap Multimode Fault Finder Dealer in Qatar
Multimode Fiber Distance and Fault Locator
- Works on multimode fiber, 50/125µm and 62.5/125 µm
- 850 nm output wavelength. Measure up to 4,921 feet (1,500 metres) of fiber in seconds
- Locate severe bends, high-loss splices, breaks and dirty connectors in multimode fiber
- Measure and locate high-loss splices
- Locate the end of a fiber
- Find potential sources of high bit error rates caused by reflectance from dirty or poor connections
- Detects live optical signals before it begins testing
- Quick set-up. Connect your fiber and press the Test button. No lengthy set-up necessary
- Find problems quickly. Six-second test time—no more blind troubleshooting that can waste hours
- Change the Index of Refraction (IOR) to improve fiber length accuracy
- Visible in dark areas. Backlighted display turns off automatically
- Removable SC adapter is easily cleaned
- Optional LC, ST and FT interchangeable adapters are available
- Long battery life, 1,500 tests (typical) from 2 AA alkaline batteries
- Rugged construction; vibration and drop tested to 1 meter
Product Description
Models | |
Operating temperature with the battery | 0ºC to 50ºC |
Non-operating temperature | -20ºC to 60ºC |
Operating relative humidity (without condensation) | 95% (10ºC to 35ºC) 75% (35ºC to 40ºC) uncontrolled < 10ºC |
Vibration | Random, 5 Hz to 500 Hz, MIL-PRF-28800F CLASS 2 |
Shock | 1 meter drop test |
Altitude | 3000m |
EMC | EN 61326-1: 2004 |
Battery type | 2 AA alkaline batteries (no battery charger) |
Battery life | 1500 tests (typical) |
Laser safety | Class 1 CDRH Complies to EN 60825-2 |
LCD type | Backlit black and white (segments) |
Index of refraction range | 1.45 to 1.5 (factory default is 1.496) |
Auto turn off | Automatically turns off after 5 minutes if no keys are pressed. Backlight turns off first. |
Factory calibration interval | None |
Output wavelengths | 850 nm ± 10 nm |
Laser classification | Class 1 CDRH Complies to EN 60825-2 |
Dynamic range | >11 dB |
Maximum distance | 1500 meters or 4921 feet |
Maximum number of incidents shown | 9 |
Distance accuracy (0 m to 1500 m or 0 ft to 4921 ft) | ± (1 m + 0.1 % x length) for reflective incidents1 ± (3 m + 0.1 % x length) for non-reflective incidents2 |
Testing speed | < 6 seconds typical |
Connector | Removable/cleanable SC adapter, UPC polish |
Fiber types tested | 50/125 µm or 62.5/125 µm multimode |
Detection of reflective incidents3 | -35 dB default threshold (User selectable: -20 dB to -45 dB in 5 dB increments) |
Reflectance accuracy4 | ± 4 dB |
Maximum reflectance measurement | -20 dB |
Detection of loss incidents5 | 0.70 dB default threshold (user-configurable from 0.5 dB to 6.1 dB in 0.2 dB increments) |
Bulkhead quality | If no fiber is attached or if the connector is dirty, the troubleshooter displays 0 m or 0 ft. |
Live fiber detection | Detects optical signals from 600 nm to 1050 nm and shows ACTIVE LINE if a signal is there. Looks for a signal every 3 seconds after the first detec-tion. +7 dB maximum input power. |
Certifications and compliance | Conforms to relevant European Union directives Conforms to relevant Australian standards Listed by the Canadian Standards Association CSA C22.2 No. 61010.1.04 Conforms to FCC Rules, Part A, Class A |
1. ± user-configurable Index of Refraction (IOR) error ± the incident location error. Incident location error for reflective incidents: ±1 m from 1 m to 1.5 km. | |
2. ± user-configurable Index of Refraction (IOR) error ± the incident location error. Incident location error for non-reflective incidents: ±2 m for lengths £15 m, otherwise ±1 m. | |
3. Finds and gives the location of an incident that has a reflectance larger than -55 dB. Detects incidents >1m after the bulkhead connector when the bulkhead reflectance is <35 dB. Detects incidents >3 m after an incident when the incident reflectance is <35 dB. | |
4. With a backscatter coefficient of -63 dB at 850 nm using a calibrated -14 dB reference. | |
5. Detects incidents >10 m after the bulkhead connector or any prior incident when the bulkhead reflectance is <-35 dB and the reflectance of any prior incident is <-35 dB. The maximum link loss prior to the incident is <7 dB. |
Reviews
There are no reviews yet.