Cisco IE-1000-6T2T-LM Industrial Ethernet 1000 Switches – Price in Qatar
The Cisco® Industrial Ethernet (IE) 1000 Series Switches are compact rugged switches aimed at operational technology (OT) users with limited IT network knowledge. The IE 1000 Series Switches provide an easy transformation from the legacy factory to digital solution. For machine builders and machine-to-machine (M2M) solutions, it is an attractive entry level product as a GUI-based, lightly-managed switch. The IE 1000 is a good fit for locations with harsh temperatures and small spaces and is Power over Ethernet (PoE) capable with zero IT management.
Product Description
IE-1000-6T2T-LM Specification |
|
Forwarding Bandwidth | • Max:2.8Gbps |
Switching Bandwidth | • Max:5.6Gbps |
Hardware
|
• DRAM: 128 MB DDR2 without ECC
• Onboard flash memory: 160 MB |
Alarm | • Alarm I/O: output connector on top panel of 4P2S and 8P2S, 1.0A@24VDC or 0.5A@48VDC |
Power consumption | 5.3W |
Connectors and cabling
|
• 100BASE-FX MMF (2 km)—TBD with engineer input
• 10/100/1000BASE-T ports: RJ-45 connectors, 4-pair Category 5 UTP cabling |
Dimensions (H x W x D)including DIN rail | 5.0”H x 1.8”W x 4.5”D (127mm H x 45.7mm W x 115mm D) |
Software features
|
LLDP, Cisco CDP aware, MSTP, STP Portfast, ICMP Vlans, static IP, Trust Ingress DSCP, COS, Priority Port, port – security, IGMP querier, DHCP server SNMP v2/v3, SNMP traps, syslog, IGMP snooping, DHCP snooping, BPDU guard, Etherchannel, Alarms, PoE capability, Smartport Macro, SPAN/Port Mirroring, Strom Control, EtherNet/IP (EDS) |
Safety Certifications
|
• UL/CSA 60950-1
• EN 60950-1 • CB to IEC 60950-1 (with country deviations) • NOM to NOM-019-SCF1 (through partners and distributors) • UL/CSA/IEC/EN 61010-2-201 • CE Marking |
Hazardous Locations
|
• ANSI/ISA 12.12.01 (Class1, Div2 A-D)
• EN 60079-0, -15 ATEX certificate (Class 1, Zone2 A-D) • IEC 60079-0, 15 (report only) • UL 60079-0, 15 • CAN/CSA C22.2 No. 60079-0, -15 * Cabinet enclosure required |
EMC Emissions and Immunity Compliance
|
• FCC 47 CFR Part 15 Class A
• EN 55022/CISPR 22 Class A • EN 55016-1-1, -1-4, -2-3 Class AVCCI Class A • RoHS compliance • AS/NZS CISPR 22 Class A, AS/NZS CISPR 24 • CISPR11 Class A, CISPR22 Class A • ICES 003 Class A • KCC Marking (Korea) • CE Marking • RCM Marking (Australia/New Zealand) • EAC Marking (Eurasian Conformity) • Anatel (Brazil) • China NAL • IEC/EN/EN61000-4-2 (Electro Static Discharge), 8kV air/6kV contact • IEC/EN 61000-4-3 (Radiated Immunity, 10 V/m 80-2000MHz, 3V/m 2000-2700MHz) • IEC/EN 61000-4-4 (Fast Transients – 2kV DC power, 2kV data line, 4kv earth) • IEC/EN 61000-4-5 (Surge 2 kV/1 kV DC power, 2 kV shielded and unshielded data line) • IEC/EN 61000-4-6 (Conducted Immunity, 10 V/emf 0.15-80MHz) • IEC/EN 61000-4-8 (Power Frequency Magnetic Field Immunity 30A/m 60 sec, 300A/m 3 sec) • IEC/EN 61000-4-9 (Pulse Magnetic Field Immunity 300A/m) • IEC/EN 61000-4-29 (Voltage Dips Immunity) |
Shock and Vibration
|
• IEC 60068-2-27 (Operational Shock: 30G 11ms, half sine)
• IEC 60068-2-27 (Non-Operational Shock 65-80G, trapezoidal) • IEC 60068-2-6, IEC 60068-2-64 (Operational Vibration) • EC 60068-2-6, IEC 60068-2-64, IEC 60068-2-47 (Non-operational Vibration) |
Industry Standard
|
• IEC/EN 61000-6-1 (Immunity for Light Industrial Environments)
• IEC/EN 61000-6-2 (Immunity for Industrial Environments) • IEC/EN 61000-6-4 (Emissions for Industrial Environments) • EN 61131-2 (PLC Zone A & B, EMC/EMI, environmental, mechanical) • EN61326-1 (Industrial Controls) • Marine –TAC (Temp-A, Humid-B, Vib-A, EMC-A, Enc-A) • EN 50581 (RoHS) • China RoHS • EU WEEE • NEMA TS-2 (EMC, environmental, mechanical) • IP30 |
Humidity
|
• IEC 60068 -2-3
• IEC 60068-2-30 (Test Db) • Relative humidity: 5% to 95% non-condensing |
Operating Temperature
|
• -20 °C to 70 °C (vented enclosure operating)
• -20 °C to 60 °C (sealed enclosure operating) • -16 °C to 75 °C (fan or blower-equipped enclosure operating)•Operational altitude: Up to 13.8k ft • IEC 60068-2-1 • IEC 60068-2-2 • IEC 60068-2-56 • -40 C to +85 C (storage temperature) • IEC 60068-2-14 (Test Nb) • Storage altitude: Up to 15,000 ft |
Mean Time Between Failure (MTBF) | • Meantime between failure: 374,052 hours (42.7 years) |
Warranty
|
• Five-year limited warranty on all IE-1000 hardware PIDs and all IE power supplies defined in Table 2 previously. See the following link for details on warranty |
Reviews
There are no reviews yet.